Skip to main content
Service hours: Monday–Friday, 08:00–17:00 WIB

VOCS Online Monitoring System GRI-1802

SKU: KIT-00072

Available

Volatile organic compounds (VOCs) are important precursors of secondary pollutants such as fine particulate matter (PM2.5) and ozone (O03), thus causing atmospheric environmental problems such as haze and photochemical smog. VOCs monitoring and realizing VOCs pollution emission reduction and effective control is the key to winning in battle to protect blue sky. For this reason, has designed GRI-1802 volatile organic compounds VOCs online monitoring system, which adopts foreign advanced imported sensors to provide accurate and stable data for all-weather real-time monitoring.

Detection principle
PID, Photo ion.
Detect gas
TVOC CO WwW ~
Sampling way
Pumping style v
Range
0-2/20/200/2000/10000 PPM (optional) GRI-1802
Resolution
Optional
Precision
S+5%FS
Repeatability
s+2%F.S
Zero drift
s+2%F.S/6h
Span drift
s+5%F.S/6h
Response time
T90<30s
Operation temperature
-20°C to +50°C
Operation humidity
0-100%
Signal
4G, GPRS signal connected to cloud platform
Gas sampling flow
500ml/min
Display
8-inch LCD
Product Size
950x550x390mm