Skip to main content
Service hours: Monday–Friday, 08:00–17:00 WIB

MH-411D NDIR Infrared CO2 Sensor

SKU: ENV-01201

Available

NDIR principle, 0-10% Vol optional, UART/analog voltage signal.

Detection gas
CO2
Working Voltage
3.6~5VDC (Need to be powered by safety barrier)
Average Current
<85mA
Detection range
0-10%vol Optional
Interface Level
3.0V
Output Signal
UART, 0.4~2V (Need to be powered by safety barrier)
Warm-up Time
3 min
Response Time
T90<30s
Working Temperature
-20C ~60C
Working Humidity
0~95%RH (no condensation)
Sizes
Phi20x22.2mm
Weight
35g
Life Time
>5 years
Defense Grade
IP54
Power/communication terminal
Intrinsic safety Ui=7.5VDC, Ii=265mA, Pi=0.5W, Ci=10uF, Li=0mH
Measuring Range/Accuracy
CO2 0~2000ppm +/-(50ppm+5% of Read Value), also 0~6000ppm, 0~1%VOL, 0~3%VOL, 0~5%VOL, all with Temperature compensation