Skip to main content
Service hours: Monday–Friday, 08:00–17:00 WIB

Fixed Gas Detector for Acetylene C2H2 Leakage Monitoring in Welding Workshop

SKU: ENV-00951

Available

Real-time concentration alarm, sound/light alarm, for acetylene leakage in welding workshops.

Gas detected
C2H2
Install method
Wall-mounted, piping type, flow-type (according to the detected environment)
Measure range
0-100%LEL
Resolution
1%LEL
Precision
± 2-5% FS
Signal output
4-20mA, 0-5V, RS485, relay(optional)
Response time
≤10S
Recovery time
≤10S
Repeatability
≤±1%
Linearity error
≤±1%
Zero shift
≤±1%(FS/year)
Display
High-light nixie tube display
Connection mode
G1/2 external thread explosion-proof flexible pipe
Unit
ppm, mg/m³, %vol
Temperature
-20 to 50°C
Humidity
0-95%RH
Explosion-proof
Ex dIICT6
Degree of protection
IP65
Alarm
Sound, light
Operating time
24H
Dimensions
180*150*90mm
Weight
≤2kg
Explosion-proof Grade
Ex D IIC T6 Gb
Thread Size
M45*2mm
Response Time(T90)
15 To 30s