Constant Voltage Residual Chlorine Meter (online transmitter)
SKU: WQ-00356
96x96 intelligent online residual chlorine transmitter. Friendly menu design, easy to operation. Three kinds of display methods can meet the different requirements of users. Provide chlorine zero calibration and slope calibration, menu design clarity. 12864 liquid crystal screen. Watchdog function to ensure the normal operation of the instrument. Applications CL-8001 Widely used for continuous monitoring of residual chlorine of various Constant Voltage water quality in power, water plants, hospitals, chemical industry, Residual Chlorine Meter food industry and other industries.
- Measuring range
- Residual chlorine: 0~2mg/l
- Temp
- 0~99.9℃
- Unit
- mg/l
- Resolution
- Residual chlorine: 0.01mg/L
- Temp
- 0.1℃
- Accuracy
- Residual chlorine: ±1% or ±0.01mg/L (take the biger)
- Temp
- ±0.5℃(0~50.0℃)
- Minimum Detection limit
- 0.01mg/L
- Repeatability
- Residual chlorine: ±0.01mg/L
- Stability
- Residual chlorine: ±0.01(mg/L)/24H
- Output current error
- ≤1%FS
- Isolated current output
- 4-20mA(load<750Ω)
- High and low alarm replays
- AC220V, 5A
- Power Supply
- 90~240V AC, 50/60Hz
- Digital output
- 4~20mA output and RS485 Modbus standard communication protocol
- Operating temperature
- 0℃~60℃, RH<85%
- Installation
- Wall, panel, pipe
- Overall size(HxWxD)
- 96mm x 96mm x 118mm
- Hole size(H x W)
- 92mm x 92mm
- Weight
- 0.5KG